GE L C,CAO Q,WANG M M,et al. Study of real gas effects on regenerative refrigeration in the liquid helium temperature range under various pressure conditions[J]. Vacuum and Cryogenics,2025,31(2):202−207. DOI: 10.12446/j.issn.1006-7086.2025.02.010
Citation: GE L C,CAO Q,WANG M M,et al. Study of real gas effects on regenerative refrigeration in the liquid helium temperature range under various pressure conditions[J]. Vacuum and Cryogenics,2025,31(2):202−207. DOI: 10.12446/j.issn.1006-7086.2025.02.010

Study of Real Gas Effects on Regenerative Refrigeration in the Liquid Helium Temperature Range under Various Pressure Conditions

More Information
  • Received Date: April 08, 2024
  • The influence of real gas effects on the performance of regenerator heat exchangers has been analyzed. An expression for the coefficient of performance (COP) of regenerators is derived. The existing body of research has been largely confined to pressures between 1 and 2 MPa, with a notable absence of insight into the manner in which the COP undergoes alteration and the nature of losses at pressures that are both higher and lower than this range. By extending the pressure range, the coefficient of performance (COP) and relative Carnot efficiency (rCOP) of regenerators under conditions of variable pressure are determined. The results demonstrate that when the cold end temperature is between 5 and 25 K, the rCOP displays a U-shaped variation with decreasing pressure. To illustrate, at a cold end temperature of 5 K, the rCOP values are 19.6%, 15.32%, and 97.64% at pressures of 2.5 MPa, 1.0 MPa, and 0.01 MPa, respectively, with the minimum rCOP occurring near the critical pressure of 0.228 MPa (0.19~0.23 MPa). Above 25 K, the relative COP increases as pressure decreases. To illustrate, when the hot end temperature is fixed at 40 K, the rCOP values are 65.7%, 81.7%, and 99.4% at pressures of 2.5 MPa, 1.0 MPa, and 0.01 MPa, respectively, when the cold end temperature is 20 K. However, below 5 K and at higher pressures, the trend is reversed. Furthermore, the issues associated with low pressure are assessed, such as low power density and significant losses. At higher pressures, both theoretical calculations and regenerative energy simulations yield higher rCOP values. The rCOP obtained from calculations and simulations is larger than the experimental data, confirming that losses are more substantial in practical applications.

  • [1]
    植晓琴,邱利民,甘智华,等. 20 K以下温区斯特林型脉管制冷机的最新研究进展与损失机理分析[J]. 低温工程,2011(2):25−33.
    [2]
    陈国邦,汤珂. 小型低温制冷机原理[M]. 北京:科学出版社,2010.
    [3]
    ZHAO T S,CHENG P. Oscillatory pressure drops through a woven-screen packed column subjected to a cyclic flow[J]. Cryogenics,1996,36(5):333−341. doi: 10.1016/0011-2275(96)81103-9
    [4]
    RADEBAUGH R,HUANG Y,O'GALLAGHER A,et al. Optimization calculations for a 30 Hz,4 K regenerator with Helium3 working fluid[C]//Transactions of the Cryogenic Engineering Conference,American Institute of Physics,2010.
    [5]
    RADEBAUGH R,ZIMMERMAN J,SMITH D R,et al. A comparison of three types of pulse tube refrigerators:New methods for reaching 60 K[J]. Advances in Cryogenic Engineering,1986,31:779−789.
    [6]
    STORCH P J,RADEBAUGH R. Development and experimental test of an analytical model of the orifice pulse tube refrigerator[J]. Advances in Cryogenic Engineering,1988,33:851−859.
    [7]
    GARY J,O'GALLAGHER A,RADEBAUGH R,et al. REGEN3.3:User manual[Z]. National Institute of Standards and Technology,2006.
    [8]
    YOSHIMURA N,ZHOU S L,MATSUBARA Y,et al. Performance dependence of 4 K pulse tube cryocooler on working pressure[M]. Springer US,2002.
    [9]
    CAO Q. Real gas effects on the COP of regenerators working at low temperatures[C]//Proceedings of the 19th International Cryocooler Conference,Boulder,America,2016.
    [10]
    CAO Q,QIU L,GAN Z. Real gas effects on the temperature profile of regenerators[J]. Cryogenics,2014,61:31−37. doi: 10.1016/j.cryogenics.2014.01.011
    [11]
    CAO Q,LUAN M K,LI P,et al. A critical review of real gas effects on the regenerative refrigerators[J]. Journal of Thermal Science,2021,30:782−806. doi: 10.1007/s11630-020-1381-4
    [12]
    李卓裴. 液氦温区斯特林型脉管制冷机回热损失机理与多级脉管级联方式研究[D]. 杭州:浙江大学,2010.
    [13]
    董文庆. 液氦温区分离型脉管制冷机的性能优化研究[D]. 杭州:浙江大学,2011.
    [14]
    曹强. 液氦温区多级斯特林型脉管制冷机理研究[D]. 杭州:浙江大学,2012.
    [15]
    阚安康,吴亦农,张安阔,等. 回热式低温制冷装置回热器填料结构概述[J]. 低温与超导,2016,44(11):28−34.

Catalog

    Article views (6) PDF downloads (2) Cited by()

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return