THE EFFECT ON TOTAL LEAKAGE MEASUREMENT USING THE PRESSURE DECREASE METHOD BECAUSE OF ENVIRONMENTAL TEMPERATURE

  • The principle of leakage measurement using differential pressure transducer is introduced. The effect of environmental temperature change is analyzed in view of the processes of differential pressure measurement. The amended formula with the temperature is givevn. the measurement method for effective volume of detected system is put forward.
  • loading

Catalog

    /

    DownLoad:  Full-Size Img  PowerPoint
    Return
    Return